Insulation Calculator
Find how thick your insulation needs to be to hit a target R-value — and how much material that means — for any common insulation type.
Insulation Calculator
R-values per inch are typical published figures (U.S. Department of Energy). Real products vary by density and manufacturer — check the label on the product you buy.
Formulas:
Thickness (in) = Target R-value ÷ R-value per inch of the material
Volume (cu ft) = Area (sq ft) × Thickness (in) ÷ 12
Volume (cu yd) = Volume (cu ft) ÷ 27
What Does an Insulation Calculator Do?
An insulation calculator works out how thick your insulation needs to be to reach a target R-value, and how much material that thickness means for the area you are insulating. You enter the area in square feet, the R-value you are aiming for, and the insulation material, and the calculator returns the required thickness in inches and centimeters, and the volume in cubic feet and cubic yards.
R-value measures resistance to heat flow: the higher the R-value, the better the insulation. Every material has an R-value per inch, and the total R-value of a layer is its R-value per inch times its thickness. That is why the same target R-value needs very different thicknesses depending on the material — R-38 needs about 12.3 inches of fiberglass batts but only 6.3 inches of closed-cell spray foam. This calculator does that division for every common material, so you can compare them on equal terms.
How to Use This Calculator
Enter the area to insulate in square feet — the floor area of the attic, or the wall area of the room. Then enter the target R-value: R-38 is a common attic target in moderate climates, R-49 in colder ones, and R-13 to R-21 for walls depending on the stud depth. Choose the material from the list, and the results update as you type, so you can switch materials and see immediately how the thickness and volume change.
The headline result is the thickness in inches. That is the number to check against the space you have: a 2x4 wall cavity is only 3.5 inches deep, so at R-3.1 per inch it holds about R-11 of fiberglass batts (3.5 × 3.1 = 10.85). Standard R-13 batts fit the same 3.5-inch cavity because they are made denser, at about R-3.7 per inch — which is why the product label, not the generic per-inch figure, is the number to trust. If the required thickness is deeper than your cavity or joist space, you need a higher-R material or a second layer.
R-Values per Inch by Material
The R-values per inch in this calculator are typical published figures from the U.S. Department of Energy. Fiberglass batts are R-3.1 per inch, and blown fiberglass is a little lower at R-2.7 per inch because the loose fibers pack less densely. Blown cellulose is R-3.7 per inch, mineral wool batts are R-3.3 per inch, and open-cell spray foam is R-3.6 per inch. Closed-cell spray foam is R-6.0 per inch, and XPS rigid board is R-5.0 per inch.
These are nominal laboratory values, and real products vary around them with density and manufacturer — fiberglass batts, for example, are published anywhere from R-3.0 to R-3.7 per inch depending on the product. Installed performance is also lower than the lab figure: gaps, compression, and heat traveling through the framing itself (thermal bridging) can reduce the whole-assembly R-value by 10 to 25% compared with the number on the bag. Treat the calculator's thickness as a minimum, and check the label on the product you actually buy.
R-value per inch matters most where depth is limited — a 2x4 wall, a rim joist, a cathedral ceiling. In an open attic, where you can add any depth you like, cost per unit of R-value matters far more, and the cheapest materials per unit R are cellulose and blown fiberglass. Closed-cell spray foam has the highest R per inch, but it costs several times more per unit of R than blown cellulose, so it only makes sense where space is tight or where its air-sealing and moisture-blocking properties are needed.
What R-Value Do I Need?
The target R-value depends on where you live and what you are insulating. Building codes set minimums by climate zone: under the International Energy Conservation Code, attic insulation ranges from R-30 in the warmest zones (south Florida, Hawaii) to R-60 in the coldest (northern Minnesota, Alaska). Walls range from R-13 in warm climates to R-20 or R-21 in cold ones, and floors over unheated spaces from R-13 to R-30.
Code minimums are minimums, not recommendations: going above them usually pays for itself in energy savings, especially in an attic, where adding insulation is cheap and easy. The U.S. Department of Energy recommends R-38 to R-60 for attics in most of the country, R-13 to R-21 for walls, and R-25 to R-30 for floors. If you are unsure what your zone requires, check the DOE's climate zone map or ask your local building department — an insulation job that fails the code minimum will fail inspection.
Worked Example
Say you are insulating a 1,000-square-foot attic to R-38 with blown cellulose, which is R-3.7 per inch. The thickness needed is 38 ÷ 3.7 = 10.27 inches. The volume is 1,000 × 10.27 ÷ 12 = 855.86 cubic feet, which is 855.86 ÷ 27 = 31.70 cubic yards.
Compare that with fiberglass batts at R-3.1 per inch: R-38 needs 38 ÷ 3.1 = 12.26 inches, and the volume is 1,000 × 12.26 ÷ 12 = 1,021.51 cubic feet — about 19% more material for the same R-value. With closed-cell spray foam at R-6.0 per inch, R-38 needs only 38 ÷ 6.0 = 6.33 inches and 527.78 cubic feet, but the material costs several times more per cubic foot. That is the trade-off this calculator makes visible: thickness, volume, and cost all move together, and the right material depends on how much space you have and how much you want to spend.
Tips for Insulating
Air-seal first. Insulation slows heat flow, but it does not stop air flow. Fiberglass and cellulose are air-permeable, so air leaking through gaps around pipes, wires, and light fixtures bypasses the insulation entirely. Seal air leaks with caulk and foam before you insulate — it is the cheapest energy improvement there is.
Do not compress batts. A batt's R-value comes from the air trapped in it. Squeezing a 6-inch batt into a 3.5-inch cavity does not give you R-19 in 3.5 inches — it gives you roughly R-13, because the compressed fibers conduct heat more easily. Use the batt thickness that matches the cavity depth.
Account for settling. Blown cellulose settles by about 10% as it reaches its rated density, and blown fiberglass settles by about 1%. Installers account for this by blowing cellulose deeper than the target thickness; if you are doing it yourself, add 10% to the depth for cellulose.
Keep insulation away from heat. Most insulation is not fireproof. Keep it at least 3 inches from recessed light fixtures unless the fixtures are rated IC (insulation contact), and keep it away from chimneys, flues, and exhaust vents. Mineral wool is the exception: it is non-combustible and is often used around hot surfaces.
Common Mistakes to Avoid
The biggest mistake is insulating over air leaks — see above. The second is mixing up R-value and thickness: R-38 is a performance target, not a depth, and the depth it needs depends entirely on the material. The third is compressing batts to fit a shallow cavity, which wastes money and R-value at the same time.
The fourth mistake is leaving gaps. Insulation only works where it is: a 5% gap in coverage can cut the effective R-value of the whole assembly by 25% or more, because heat takes the path of least resistance. Cut batts to fit snugly around obstacles, and do not leave bare patches at the edges of the attic. Finally, do not block soffit vents with insulation: attics need ventilation to control moisture, and a blocked vent causes condensation, mold, and ice dams in winter. Use baffles to hold the insulation back from the vents.
Results from this calculator are estimates for planning and ordering. Check the label on the product you buy for its rated R-value per inch, and check your local building code for the required R-values in your climate zone.
Frequently Asked Questions
How thick does insulation need to be for R-38?
It depends on the material: 12.26 inches of fiberglass batts (R-3.1 per inch), 10.27 inches of blown cellulose (R-3.7 per inch), or 6.33 inches of closed-cell spray foam (R-6.0 per inch). Thickness = target R-value / R-value per inch.
What is the R-value of fiberglass batts per inch?
About R-3.1 per inch, the typical published figure from the U.S. Department of Energy. Real products range from about R-3.0 to R-3.7 per inch depending on density.
What is the R-value of blown cellulose per inch?
About R-3.7 per inch at settled density. Cellulose settles by about 10% after installation, so installers blow it deeper than the target thickness.
What R-value do I need for an attic?
The U.S. Department of Energy recommends R-38 to R-60 for attics in most of the country, and building codes require R-30 to R-60 depending on your climate zone. Cold climates need the higher end.
Can I compress a thick batt into a shallow wall cavity?
You can, but you lose R-value: squeezing a 6-inch batt into a 3.5-inch cavity gives roughly R-13, not R-19, because the compressed fibers conduct heat more easily. Use the batt thickness that matches the cavity depth.